Konferenca o izolatorjih za transformatorske postaje

Nov 30, 2021 Pustite sporočilo

Nedavno je v starodavnem mestu Dunhuang potekala konferenca o izolatorjih za transformatorske postaje. Razlog, zakaj je ta oddaljena puščavska oaza postala prizorišče srečanja, je bila nenavadna 750 kV testna transformatorska postaja v bližini, in sicer transformatorska postaja Shazhou. Tisto, zaradi česar je postaja Shazhou tako edinstvena, so prve postaje, v katerih je vsa oprema v postaji izolirana s kompozitnimi plašči, od puš do odvodnikov, od transformatorjev do stebrov postaje in tako naprej.


Na srečanju so obravnavali širok spekter tem. Profesor Liang Xidong z univerze Tsinghua je na primer poročal, da je uporaba kompozitnih izolatorjev na Kitajskem od devetdesetih let 20. stoletja močno pripomogla k zmanjšanju nesreč zaradi preplahov. Song Shengli iz državne omrežne korporacije je tudi predlagal, da glede na tipično surovo okolje na številnih območjih Kitajske porcelanski izolatorji za enosmerni tok običajno zahtevajo enakomerno plazilno pot (USCD) do 86 mm/kV. Predlagal je, da če se namesto porcelanskih izolatorjev uporablja kompozitni plašč, za zgoraj omenjene aplikacije zadostuje manj kot 50 mm/kV. Poudaril je tudi specifične probleme, ki jih je treba rešiti s to tehnologijo, kot so uhajanje plina iz ohišja SF6, preboj ledu in snega ter mehanske obremenitve UHV opreme. Srečanje je organiziral Fang Jiang, strokovnjak za domače proizvajalce kompozitnih izolatorjev. Pregledal je raziskave, ki jih je izvedel ključni laboratorij za kompozitne materiale in komponente kitajskega raziskovalnega inštituta za električno energijo, s ciljem optimizacije dizajna plašča. Povzel je tudi tehnologijo za zmanjšanje tveganja poškodb izolatorjev zaradi ptic ali glodalcev in doslej med 300000 kompozitnimi izolatorji, ki jih proizvaja ta tovarna, ni bilo resnih primerov kljuvanja ali grizenja.


Ravi Gorur z univerze Arizona State je na srečanju tudi poudaril, da v nasprotju s Kitajsko očiten trend, ki ZDA spodbuja k sprejetju velikega števila kompozitnih jopičev, ni zaradi njihove odlične odpornosti proti madežem, temveč z vidika njihove varnosti in stroškovne koristi. . Po besedah ​​Gorurja ameriška elektroenergetska podjetja zdaj še bolj sprejemajo kompozitne plašče kot izolatorje. Stanislaw Gubanski iz Švedske je prav tako poudaril, da je treba zagotoviti, da se kompozitni izolatorji dobro obnesejo ne le v onesnaženih okoljih, temveč tudi v drugih delovnih okoljih. Poročali so na primer, da mikroorganizmi rastejo na tej vrsti jakne v tropskih in vlažnih območjih, a ker ne povzroča razgradnje materialov iz silikonske gume in ima običajno omejen vpliv na električne lastnosti, se ne šteje za resno grožnjo.


Luo Bing introduced some research carried out by China Southern Power Grid, and reported on the DC operation experience. At present, it is almost common practice to use composite jackets in domestic substations. He also pointed out that because composite post insulators have more advantages than porcelain insulators, they are now increasingly used. Based on 6 years of operating experience, more than 1,000 composite post insulators installed in UHV/UHV DC have performed well. He did mention some of the aging problems of composite outer sleeves made of liquid silicone rubber (LSR), including local hardening, cracking and loss of hydrophobicity. Pollution flashovers and rain flashovers also occurred in a small number of jackets with too small distance between umbrella skirts. However, based on experience, the pollution test is usually more stringent, so a properly designed anti-fouling insulator should be considered to have sufficient performance to operate well under heavy rain. He suggested that, based on this, the DC insulator umbrella pitch/overhanging distance (S/P) ratio>0.9, najmanjša razdalja med velikimi robovi dežnika mora biti vsaj 70 mm, najboljša razdalja pa je 90 mm.


Zhou Jun iz kitajskega raziskovalnega inštituta za električno energijo je prav tako poročal o njihovem raziskovalnem delu, vključno z dolgoročnim testiranjem kompozitnih jopičev, ki so jih izdelali različni proizvajalci na visokogorskih območjih v Tibetu. Poudaril je, da je Kitajska izdala veliko novih standardov za kompozitne izolatorje, ki so pred IEC. Denis Chattrefou iz Alstoma je omenil, da je med drugim treba integrirati optična vlakna v kompozitni stebrični izolator, ki je bistveni del netradicionalnih digitalnih senzorjev.


Nazadnje sta Zhu Anming iz državne mreže Kitajske in Yu Bo iz CPECC skupaj pregledala različne tehnične in ekonomske podlage za uporabo kompozitnih stebrnih izolatorjev in plaščev v celotni transformatorski postaji Shazhou. Prvič, ti jopiči morajo prestati stroge teste, ki simulirajo surovo puščavsko delovno okolje postaje. Kasnejša primerjava ekonomskih izračunov pokaže, da je to boljša rešitev glede na skupni strošek nabave in življenjski cikel.


Nato sem obiskal 750 kV testno postajo Sazhou, ki deluje od leta 2013, kar je govornikom in drugim gostom omogočilo, da so cenili njene edinstvene lastnosti in težke pogoje na lokaciji. To srečanje mi je pomagalo jasno razumeti trenutno stanje kompozitnih jopičev in me prepričalo, da ta trenutno zrela tehnologija izdelkov postaja vse bolj konkurenčna.